skip to footer block
MEO ICM Controls ICM288 Furnace Control Module For Rheem P7566715MEO-286163 https://cdnimages.opentip.com/full/MEO/MEO-286163.jpg ICM Controls ICM288 Furnace Control Module For Rheem Manufacturer Part Number: ICM288ICMICM288 Furnace Control Module For RheemPart Description:Furnace Control Module Type Microprocessor Based Ignition Trial Time 10 Second Prepurge Time 60 Second Valve Rating 1 Amp at 24 Volt AC (Gas Valve) Power Rating 98 to 132 Volt AC at 60 Hertz (Line) Size 7.5 Inch Length x 5.75 Inch Width x 1.5 Inch Height Application Furnace Approval UL (Canada and US) Output Rating 5 Amp at 120 Volt AC (Igniter), 10 Amp, 2 HP at 240 Volt AC (Cool Blower), 5 Amp, 1/2 HP at 240 Volt AC (Heat), 4 Amp at 120 Volt AC (Inducer Motor), 0.5 Amp at 24 Volt AC (Humidifier Motor), 1 Amp at 120 Volt AC (Electronic Air Cleaner)Features / BenefitsLow Cost Form, Fit and Functional Replacement for Rheem 62-24084-82 Circuit Boards Microprocessor Based Design Monitors Pressure, Roll-Out and Limit Switches Controls Gas Valve, Inducer Draft Motor, Circulating Blower and Hot Surface Igniter Reverse Polarity Detection Twinning Compatible with Other ICM288 Control Boards Diagnostic LEDs for Testing/Troubleshooting Made in USA 7566715 00800442028095 2.4000lbs 0.00 0.00 0.00
ICM Controls
193.9900 2026-12-24 5 In Stock
customer review - by , December 12, 2025
5/ 5stars
As promised.
customer review - by , November 11, 2025
5/ 5stars
worked well ..easy install. thanks
customer review - by , November 11, 2025
4/ 5stars
Did not use it, sent it back. Got a new furnace
customer review - by , October 10, 2025
5/ 5stars
As advertised. Works great.
customer review - by , October 10, 2025
5/ 5stars
90's Rheem Furnace Model RGDG-10NBRJR, OEM 7.534; X 5.7534; Furnace Control Board 34;62- 24084-8234; was smoked. Ordered replacement Control Module ICM288. Simple easy instructions included. ICM Module is same size as the OEM Module and same mounting holes 34;Sweet34;. ICM's Module wire connections are marked/labeled same has OEM Module. My older furnace needed the upgrade of an additional Remote Flame Sensor 34;62-24044-7134;. Both the Furnace Control Board and Remote Flame Sensor were easy installs. Furnace is up running with no issues.
customer review - by , July 7, 2025
5/ 5stars
good product
customer review - by , June 6, 2025
5/ 5stars
very close to the original, installed easy, works great
customer review - by , May 5, 2025
5/ 5stars
Worked like a charm. Maybe a 15 minute install. There was a slight difference in terminal location from OEM board that it replaced but the terminals were clearly marked and not hard to figure out what wires went where. In my application, itt did require a new fire sensor but that was super simple to install too. Once I removed the old board, microscopic inspection revealed that the only problem with the old board were cracked solder joints on the Molex connectors after 24 years of service. A quick touch up and I now have a spare board. Still glad I bought the new one. The house was freezing.
customer review - by , April 4, 2025
5/ 5stars
I have 3 Ruud furnaces, all of which use these control boards. Over the past 2 years I've had to replace the control boards on 2 of them (after 20 years of service). This control board works perfectly in my Ruud furnace, and was easy to install. Sometimes things just look too good to be true, but this board is 34;the real deal34;, and I got what I consider the 34;deal of the year34; on this board. By not having to rely on a furnace repair person to come out and sell me a 34;factory approved replacement board at full retail34;, I saved a crap load of money. Thank you so much for offering such a high quality product at such a fantastic price! I am in no way affiliated with the seller, or manufacturer of this product, but feel compelled to let everyone know that this is really a great deal. It's going to take something really special to 34;wow34; me like this control board has. The schematic and installation instructions are in 34;ENGLISH34;, without the 34;grammatical errors34; so often found with cheap imported electronics. ICM Controls ICM288 Furnace Control, Low Cost Replacement for Rheem 62-24084-82 Control Boards
customer review - by , April 4, 2025
5/ 5stars
Used this to replace my old RHEEM board 62-24044-01. It was a a pretty simple change, just make you take a picture of your wires before you disconnect them all. I had a HVAC friend price a new board and it was $200.00 wholesale, so you can't beat the price!

ICM Controls ICM288 Furnace Control Module For Rheem, Price/each

stars Rating 5 | 19 reviews
Brand ICM Controls
Shop more from MEO

UPC: 00800442028095
SKU: MEO-286163
Price: $193.99
Quantity:
5 In Stock
*  Click "Add to Cart" to calculate shipping and delivery time.
Share & Earn 10% Cash Back Best Price in Bulk

You may also like

Product Description

Price is for each.

Manufacturer Part Number: ICM288

ICMICM288 Furnace Control Module For Rheem

Part Description:
  • Furnace Control Module
  • Type Microprocessor Based
  • Ignition Trial Time 10 Second
  • Prepurge Time 60 Second
  • Valve Rating 1 Amp at 24 Volt AC (Gas Valve)
  • Power Rating 98 to 132 Volt AC at 60 Hertz (Line)
  • Size 7.5 Inch Length x 5.75 Inch Width x 1.5 Inch Height
  • Application Furnace
  • Approval UL (Canada and US)
  • Output Rating 5 Amp at 120 Volt AC (Igniter), 10 Amp, 2 HP at 240 Volt AC (Cool Blower), 5 Amp, 1/2 HP at 240 Volt AC (Heat), 4 Amp at 120 Volt AC (Inducer Motor), 0.5 Amp at 24 Volt AC (Humidifier Motor), 1 Amp at 120 Volt AC (Electronic Air Cleaner)


Features / Benefits

  • Low Cost Form, Fit and Functional Replacement for Rheem 62-24084-82 Circuit Boards
  • Microprocessor Based Design
  • Monitors Pressure, Roll-Out and Limit Switches
  • Controls Gas Valve, Inducer Draft Motor, Circulating Blower and Hot Surface Igniter
  • Reverse Polarity Detection
  • Twinning Compatible with Other ICM288 Control Boards
  • Diagnostic LEDs for Testing/Troubleshooting
  • Made in USA

warning tips WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov.

Note

This product is not eligible for coupon code discount, for we've been offering the best price in the market.
Need more information?
Our staff are available to answer any questions you may have about this item


Customer Reviews
By Roy T Tolbert
Date: June 19, 2025
very close to the original, installed easy, works great
Rating: 5 stars [5 of 5 Stars!]
By Fran Crea
Date: May 24, 2025
Worked like a charm. Maybe a 15 minute install. There was a slight difference in terminal location from OEM board that it replaced but the terminals were clearly marked and not hard to figure out what wires went where. In my application, itt did require a new fire sensor but that was super simple to install too. Once I removed the old board, microscopic inspection revealed that the only problem with the old board were cracked solder joints on the Molex connectors after 24 years of service. A quick touch up and I now have a spare board. Still glad I bought the new one. The house was freezing.
Rating: 5 stars [5 of 5 Stars!]
By Jim from Acworth, GA
Date: April 26, 2025
I have 3 Ruud furnaces, all of which use these control boards. Over the past 2 years I've had to replace the control boards on 2 of them (after 20 years of service). This control board works perfectly in my Ruud furnace, and was easy to install. Sometimes things just look too good to be true, but this board is 34;the real deal34;, and I got what I consider the 34;deal of the year34; on this board. By not having to rely on a furnace repair person to come out and sell me a 34;factory approved replacement board at full retail34;, I saved a crap load of money. Thank you so much for offering such a high quality product at such a fantastic price! I am in no way affiliated with the seller, or manufacturer of this product, but feel compelled to let everyone know that this is really a great deal. It's going to take something really special to 34;wow34; me like this control board has. The schematic and installation instructions are in 34;ENGLISH34;, without the 34;grammatical errors34; so often found with cheap imported electronics. ICM Controls ICM288 Furnace Control, Low Cost Replacement for Rheem 62-24084-82 Control Boards
Rating: 5 stars [5 of 5 Stars!]
By Padme
Date: April 23, 2025
Used this to replace my old RHEEM board 62-24044-01. It was a a pretty simple change, just make you take a picture of your wires before you disconnect them all. I had a HVAC friend price a new board and it was $200.00 wholesale, so you can't beat the price!
Rating: 5 stars [5 of 5 Stars!]
By Murf the Surf
Date: February 08, 2025
Our furnace quit and I need a new control board now. The OEM was priced way to high and I found this replacement and a very fair price. I use to be a HVAC guy and I had no problem installing this. I did have to get the Flame sensor kit which also was just right and easy to install. Be sure to take several photos of your old board prior to removal and watch some of the Youtube videos prior to installation. If you are not experienced in understanding some wiring and functions of a control board I suggest hiring someone. My furnace now works better with this board than it did with the OEM board.
Rating: 5 stars [5 of 5 Stars!]
By Sid S
Date: December 26, 2024
Worked just fine for my 25 year old Rheem furnace model RGDG-07EAMGR; but it should work on other models too. I had a Honeywell furnace control board inside that was burnt out in one corner. I did notice that a lot of these boards work the same way even though they are from different board manufacturers or go into different furnace brands. In my case, I also needed to buy a flame sensor kit since my furnace was pre-1994 and lacked that no-mandatory safety feature. That retrofit is also simple but back to this, here is what I would suggest. Take plenty of pictures of your existing wires/connections, possibly putting a black sharpie dot if you've got multiple wires of the same color (obviously do this before taking the pics!). Then simply plug them back on this board! Note that even if the new boards connectors aren't at the exact same position, they will still be marked - so the wire going into (example) 34;HEAT34; on your old board will still go into the connector marked 34;HEAT34; on the new board. You can also download the PDF of this board from the product page for reference. It's surprisingly easy!
Rating: 5 stars [5 of 5 Stars!]
Items 7 - 12 of 19 reviews