skip to footer block
MEO Cleveland Controls AFS 262 112 SPDT Switch w/ Barb Connection .05" 2.0" W/C 28470 P15893860MEO-380568 https://cdnimages.opentip.com/full/MEO/MEO-380568.jpg Cleveland Controls AFS 262 112 SPDT Switch w/ Barb Connection .05" 2.0" W/C 28470 Manufacturer Part Number: AFS-262-112Part Description:CLEAFS-262-112 SPDT Switch w/ Barb Connection (.05 - 2.0 W/C) 28470These pressure switches can be used to sense positive, negative, or differential air pressures. The A/AFS-222 has a field adjustable operating range of 0.07\" to 12.0\" W.C.. The AFS-222 has a field adjustable setpoint range of 0.05\" +/- 0.02\" to 12\" W.C. with a field adjustable release range of 0.04\" to 11.2\" of W.C.. The AFS-222 will accept a 0.25\" O.D. rigid metallic tubing via the integral compression ferrule and nut. The enclosure cover guards against accidental contact with the live switch terminal screws and the setpoint adjusting screw. It also contains a 1/2\" conduit knockout in the cover of the enclosure. ACI differential air pressure switches are designed for HVAC, Building Automation, or light industrial systems. Typical applications include: building static pressure, filter monitoring, and proof of air flow. Specifications Input Pressure Range AFS-262: 0.05 +/- 0.02\" to 2.0\" wc Set Point Range AFS-262: 0.07\" to 2.0\" wc Field Adjustable \"Operate\" Range AFS-262: 0.07\" to 2\" wc Field Adjustable \"Release\" Range AFS-222: 0.04\" to 11.2\" wc Approximate Switching Differential Progressive, increasing from 0.02 +/- 0.01\" wc @ minimum set point to 0.8\" wc @ maximum set point Contact (Load) Rating AFS262: 300 VA pilot duty @ 115 to 277 VAC, 60 Hz; 15A non-inductive to 277 VAC, 60 Hz Contact Arrangement AFS-262: SPDT w/ Automatic Reset Media Types AFS-262: Air or combustion by-products that will not degrade silicone Maximum Pressure 0.5 PSI (0.03 Bar) Life Expectancy AFS-262: 100,000 cycles minimum @ 1/2 psi (0.03 Bar) max pressure / cycle & max load Operating Temperature Range -40 to 180oF (-40 to 82oC) Operating Temperature Range 10 to 95% RH, non-condensing Mounting Direction Any vertical plane Enclosure Material Galvanized Steel Sample Line Connections Accepts ¼\" OD rigid or semi-rigid metallic tubing using integral compression fitting, ferrule and nut\"-112 Option\": Includes two barbed fittings that accepts ¼\" flexible plastic tubing Electrical Connections Screw type terminal with cup washers Conduit Knockouts Accepts ½\" Conduit (7/8\" (22.3 mm) opening) Dimensions (H x W x D) 6.25\" x 4.46\" x 3.18\" (158.8 mm x 113.3 mm x 80.8 mm) Product Weight 1.2 lbs (0.544 kg) Agency Approvals UL, CUL, FM, CSA, CE, ISO 9001: 2008 Datasheets ACI AFS Differential Pressure Switch Data Sheet ACI AFS Differential Pressure Switch Installation Sheet 15893860 3.6000lbs 0.00 0.00 0.00
Cleveland Controls
50.9700 2026-08-23 Only 3 left In Stock

Cleveland Controls AFS-262-112 SPDT Switch w/ Barb Connection (.05" - 2.0" W/C) 28470

Shop more from MEO

SKU: MEO-380568
Price: $50.97
Quantity:
Only 3 left In Stock
*  Click "Add to Cart" to calculate shipping and delivery time.
Share & Earn 10% Cash Back Best Price in Bulk

Product Description

Manufacturer Part Number: AFS-262-112

Part Description:
CLEAFS-262-112 SPDT Switch w/ Barb Connection (.05 - 2.0 W/C) 28470

These pressure switches can be used to sense positive, negative, or differential air pressures. The A/AFS-222 has a field adjustable operating range of 0.07" to 12.0" W.C.. The AFS-222 has a field adjustable setpoint range of 0.05" +/- 0.02" to 12" W.C. with a field adjustable release range of 0.04" to 11.2" of W.C.. The AFS-222 will accept a 0.25" O.D. rigid metallic tubing via the integral compression ferrule and nut. The enclosure cover guards against accidental contact with the live switch terminal screws and the setpoint adjusting screw. It also contains a 1/2" conduit knockout in the cover of the enclosure. ACI differential air pressure switches are designed for HVAC, Building Automation, or light industrial systems. Typical applications include: building static pressure, filter monitoring, and proof of air flow. Specifications Input Pressure Range AFS-262: 0.05 +/- 0.02" to 2.0" wc Set Point Range AFS-262: 0.07" to 2.0" wc Field Adjustable "Operate" Range AFS-262: 0.07" to 2" wc Field Adjustable "Release" Range AFS-222: 0.04" to 11.2" wc Approximate Switching Differential Progressive, increasing from 0.02 +/- 0.01" wc @ minimum set point to 0.8" wc @ maximum set point Contact (Load) Rating AFS262: 300 VA pilot duty @ 115 to 277 VAC, 60 Hz; 15A non-inductive to 277 VAC, 60 Hz Contact Arrangement AFS-262: SPDT w/ Automatic Reset Media Types AFS-262: Air or combustion by-products that will not degrade silicone Maximum Pressure 0.5 PSI (0.03 Bar) Life Expectancy AFS-262: 100,000 cycles minimum @ 1/2 psi (0.03 Bar) max pressure / cycle & max load Operating Temperature Range -40 to 180oF (-40 to 82oC) Operating Temperature Range 10 to 95% RH, non-condensing Mounting Direction Any vertical plane Enclosure Material Galvanized Steel Sample Line Connections Accepts ¼" OD rigid or semi-rigid metallic tubing using integral compression fitting, ferrule and nut"-112 Option": Includes two barbed fittings that accepts ¼" flexible plastic tubing Electrical Connections Screw type terminal with cup washers Conduit Knockouts Accepts ½" Conduit (7/8" (22.3 mm) opening) Dimensions (H x W x D) 6.25" x 4.46" x 3.18" (158.8 mm x 113.3 mm x 80.8 mm) Product Weight 1.2 lbs (0.544 kg) Agency Approvals UL, CUL, FM, CSA, CE, ISO 9001: 2008 Datasheets ACI AFS Differential Pressure Switch Data Sheet ACI AFS Differential Pressure Switch Installation Sheet

warning tips WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov.
Need more information?
Our staff are available to answer any questions you may have about this item


Customer Reviews
0 reviews
Be the first to review this item!