skip to footer block
PEX Audiomatica CLIO Pocket Version 2.1 Personal Acoustic Measurement System P5958991PEX-390-900 https://cdnimages.opentip.com/full/PEX/PEX-390-900.jpg Audiomatica CLIO Pocket Version 2.1 Personal Acoustic Measurement System Manufacturer Part Number: CLIO PocketCLIO pocket is a portable electro-acoustical multi-platform personal measurement system from Audiomatica, Italy\'s audio test equipment leader. This powerful, rugged, and lightweight portable acoustic measuring, testing, and analysis setup uses a USB connection for maximum compatibility. Version 2.1 is now available with an improved user interface and more flexibility than ever.Key Features: A complete loudspeaker measurement and testing system for professionals and hobbyists Accurately and easily determines Thiele-Small parameters Measures amplitude, frequency, time calibrated response, and distortion Hardware and software compatible with Windows and Apple Mac OSX Includes plastic case, audio interface, precision microphone, and required cables Audiomatica CLIO Pocket Version 2.1 Personal Acoustic Measurement SystemCLIO Pocket 2.1 is Audiomatica\'s portable loudspeaker testing and measurement system. From measuring capacitors and calculating T/S parameters, to measuring the frequency response of a finished speaker, CLIO Pocket can do it all! The completely revamped software has a redesigned user interface that\'s optimized for touch screens, with a modern and easy-to-use feel. This convenient system operates via multi-platform software, making it compatible with both Windows and Apple operating systemsThe CLIO Pocket 2.1 system includes a plastic carrying case, CP-01 Audio Interface, MIC-02 precision microphone, CLIO Pocket CD with software and drivers, a USB 2.0 cable, microphone cable, and test leads with alligator clips.For easy setup and calibration of the MIC-02 microphone see Measurements:Version 2 adds the capability to measure second harmonic, third harmonic and total harmonic distortion Amplitude, frequency and time calibrated responsePhase response (Normal, Minimum and Excess)Group delay response (Normal, Minimum and Excess) Time impulse responseStep responseSchroeder impulse decay Energy time curveQuasi-Anechoic acoustic response with time window selectionReal-Time fraction-of-octave analyzer (RTA)Interactive L-C-R meterFree-running voltmeter and sound level meter with bar graphDecay analysis with 3D gesture-controlled swiveling graphFree air T/S parameters Added Mass or Known Volume methods for Vas estimationAnd more PC Configuration:The CLIO CP-01 audio interface running the CLIO Pocket software can be installed on any computer with the following system specs:Pentium IV class processor (suggested minimum 2 GHz)One free USB 2.0 port1024 x 786 video adapterMicrosoft Windows (XP or newer) or Apple Mac OSX (10.15 or newer) Technical Specifications:CP-01 Audio Interface:Generator:24 bit sigma-delta D/A converterFrequency range: 1 Hz - 45 kHzFrequency accuracy: better than 0.01%Frequency resolution: 0.01 HzOutput impedance: 150 ohmMax output level (Sine): 13 dBu (3.46V RMS)Attenuation: 0.1 dB steps to full muteTHD+Noise (Sine): 0.008% AC Analyzer:24 bit sigma-delta A/D converterInput range (full scale): +40 dBV down to -40 dBVMax input acceptance: +40 dBV (283V p-p)Input impedance: 64k ohm (5.6k ohm mic)Phantom power supply: 8.2VDA Analyzer:12 bit A/D converterInput range: ±6.5VMiscellaneous:Sampling frequencies: 96 kHz and 48 kHzConnections: analog RCA in and outDigital connection: USB 2.0 portPower supply: USB powered (480 mA)(283 V p-p)Dimensions (H x W x D): 25 mm x 90 mm x 120 mmWeight: 0.3 kgMIC-02 Microphone:Type: Condenser electretAccuracy: ±1 dB, 20 Hz to 10 kHz±2 dB, 10 kHz to 20 kHz (direct field)Maximum level: 130 dB SPLDimensions (Dia x L): 8 mm x 120 mmProduct Details BrandAudiomatica ModelCLIO Pocket Part Number390-900 UPC848864023540 Unit of MeasureEach Weight2.05 5958991 848864023540 2.4600lbs 0.00 0.00 0.00
Audiomatica
871.1800 2025-04-26 10 In Stock

Audiomatica CLIO Pocket Version 2.1 Personal Acoustic Measurement System

Brand Audiomatica
Shop more from PEX

UPC: 848864023540
SKU: PEX-390-900
Price:
$871.18Free shipping on orders over $65 on select PEX- items. Details
Quantity:
10 In Stock
*  Click "Add to Cart" to calculate shipping and delivery time.
Share & Earn 10% Cash Back Best Price in Bulk

Pricing Note

Free Shipping Promotion: Buy more items from the same series, product code beginning with PEX-, and you can get free shipping for an order of over  $65.00  consisting of only PEX- series products.

Product Description

Manufacturer Part Number: CLIO Pocket

CLIO pocket is a portable electro-acoustical multi-platform personal measurement system from Audiomatica, Italy's audio test equipment leader. This powerful, rugged, and lightweight portable acoustic measuring, testing, and analysis setup uses a USB connection for maximum compatibility. Version 2.1 is now available with an improved user interface and more flexibility than ever.

Key Features:
  • A complete loudspeaker measurement and testing system for professionals and hobbyists
  • Accurately and easily determines Thiele-Small parameters
  • Measures amplitude, frequency, time calibrated response, and distortion
  • Hardware and software compatible with Windows and Apple Mac OSX
  • Includes plastic case, audio interface, precision microphone, and required cables


Audiomatica CLIO Pocket Version 2.1 Personal Acoustic Measurement System

CLIO Pocket 2.1 is Audiomatica's portable loudspeaker testing and measurement system. From measuring capacitors and calculating T/S parameters, to measuring the frequency response of a finished speaker, CLIO Pocket can do it all! The completely revamped software has a redesigned user interface that's optimized for touch screens, with a modern and easy-to-use feel. This convenient system operates via multi-platform software, making it compatible with both Windows and Apple operating systems

The CLIO Pocket 2.1 system includes a plastic carrying case, CP-01 Audio Interface, MIC-02 precision microphone, CLIO Pocket CD with software and drivers, a USB 2.0 cable, microphone cable, and test leads with alligator clips.

For easy setup and calibration of the MIC-02 microphone see
  • Version 2 adds the capability to measure second harmonic, third harmonic and total harmonic distortion
  • Amplitude, frequency and time calibrated response
  • Phase response (Normal, Minimum and Excess)
  • Group delay response (Normal, Minimum and Excess)
  • Time impulse response
  • Step response
  • Schroeder impulse decay
  • Energy time curve
  • Quasi-Anechoic acoustic response with time window selection
  • Real-Time fraction-of-octave analyzer (RTA)
  • Interactive L-C-R meter
  • Free-running voltmeter and sound level meter with bar graph
  • Decay analysis with 3D gesture-controlled swiveling graph
  • Free air T/S parameters
  • Added Mass or Known Volume methods for Vas estimation
  • And more

The CLIO CP-01 audio interface running the CLIO Pocket software can be installed on any computer with the following system specs:
  • Pentium IV class processor (suggested minimum 2 GHz)
  • One free USB 2.0 port
  • 1024 x 786 video adapter
  • Microsoft Windows (XP or newer) or Apple Mac OSX (10.15 or newer)
  • 24 bit sigma-delta D/A converter
  • Frequency range: 1 Hz - 45 kHz
  • Frequency accuracy: better than 0.01%
  • Frequency resolution: 0.01 Hz
  • Output impedance: 150 ohm
  • Max output level (Sine): 13 dBu (3.46V RMS)
  • Attenuation: 0.1 dB steps to full mute
  • THD+Noise (Sine): 0.008%
  • 24 bit sigma-delta A/D converter
  • Input range (full scale): +40 dBV down to -40 dBV
  • Max input acceptance: +40 dBV (283V p-p)
  • Input impedance: 64k ohm (5.6k ohm mic)
  • Phantom power supply: 8.2V
  • 12 bit A/D converter
  • Input range: ±6.5V
  • Sampling frequencies: 96 kHz and 48 kHz
  • Connections: analog RCA in and out
  • Digital connection: USB 2.0 port
  • Power supply: USB powered (480 mA)(283 V p-p)
  • Dimensions (H x W x D): 25 mm x 90 mm x 120 mm
  • Weight: 0.3 kg
  • Type: Condenser electret
  • Accuracy: ±1 dB, 20 Hz to 10 kHz
  • ±2 dB, 10 kHz to 20 kHz (direct field)
  • Maximum level: 130 dB SPL
  • Dimensions (Dia x L): 8 mm x 120 mm


warning tips WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov.
Need more information?
Our staff are available to answer any questions you may have about this item


Look Similar Items By Category


Customer Reviews
0 reviews
Be the first to review this item!