CED Hammond P T1182 18 Transformer Hammond Toroidal Power 18V / 36V secondary P13093682CED-P-T1182F18 https://cdnimages.opentip.com/full/CED/CED-P-T1182-18.jpg Hammond P T1182 18 Transformer Hammond Toroidal Power 18V / 36V secondary Manufacturer Part Number: P-T1182-18Dual 117/234 VAC primary, 50/60 Hz. operation. 36 V series, 18 V parallel secondary.Toroidal transformers arelow profilelightweightcool running / high efficiencyhave low stray magnetic flux leakage (low EMI) due to core shapeFeatures:Supplied with two neoprene rubber insulating pads, one metal centering washer and all mounting hardwareMinimum 8\" long flexible leadsManufactured using Class B (130 degree C) materials.Hi-Pot test of 4,000VAC RMS between primary & secondaryUL recognized to UL506 (XPTQ2.Guide) UL file #E207860CSA certified to C22.2 #66 - CSA file #209651CE compliant to IEC 61558-2-4Note: Units are designed to have all windings engaged (either series or parallel connected) or connected as an autotransformer.Note about Inrush Current: Due to the superior magnetic properties of Toroidal transformers they will be susceptible to high magnetizing current when initially energized, only limited by the low DC resistance of the primary winding. Depending on where you are in the AC cycle when the transformer is energized dictates the chances of overloading the supply circuit. This is why the transformer may sometimes energize without a problem and other times it will blow the fuse or trip the circuit breaker. The duration of this overload is rarely longer than a half of a cycle. Therefore, you should consider using a slow-blow fuse, time delayed circuit breaker or other form of soft start circuitry for the supply line when using these high efficient Toroidal transformers.Part No.VAVAC Secondary (RMS)Dual or Single Secondary% Voltage RegulationToroid CenterSeriesParallelP-T1182F181536V C.T. @ 0.420A18V @ 0.84ADual11.7%OpenP-T1182H183036V C.T. @ 0.83A18V @ 1.66ADual12.20%OpenP-T1182J185036V C.T. @ 1.39A18V @ 2.78ADual13.80%OpenP-T1182L188036V C.T. @ 2.22A18V @ 4.44ADual10.50%OpenP-T1182M1812036V C.T. @ 3.33A18V @ 6.66ADual7.70%OpenP-T1182N1816036V C.T. @ 4.44A18V @ 8.88ADual7.70%OpenP-T1182G1822536V C.T. @ 6.25A18V @ 12.5ADual7.30%OpenFor other toroidal secondary voltages, see our other listings:VoltageProduct6V parallel / 12V series secondaryP-T1182-69V parallel / 18V series secondaryP-T1182-912V parallel / 24V series secondaryP-T1182-1215V parallel / 30V series secondaryP-T1182-1518V parallel / 36V series secondaryP-T1182-1822V parallel / 44V series secondaryP-T1182-2224V parallel / 48V series secondaryP-T1182-2430V parallel / 60V series secondaryP-T1182-3040V parallel / 80V series secondaryP-T1182-4060V parallel / 120V series secondaryP-T1182-6090V parallel / 180V series secondaryP-T1182-90110V parallel / 220V series secondaryP-T1182-110117V parallel / 234V series secondaryP-T1182-117240V secondaryP-T1182-240Measurements and Specs % Voltage Regulation15 versionP-T1182F1811.70% 30 versionP-T1182H1812.20% 50 versionP-T1182J1813.80% 80 versionP-T1182L1810.50% 120 versionP-T1182M187.70% 160 versionP-T1182N187.70% 225 versionP-T1182G187.30% Height15 versionP-T1182F181.2 in. 30 versionP-T1182H181.25 in. 50 versionP-T1182J181.5 in. 80 versionP-T1182L181.5 in. 120 versionP-T1182M181.63 in. 160 versionP-T1182N181.75 in. 225 versionP-T1182G181.88 in. Inside Diameter15 versionP-T1182F181.25 in. 30 versionP-T1182H181.50 in. 50 versionP-T1182J181.25 in. 80 versionP-T1182L181.6 in. 120 versionP-T1182M181.45 in. 160 versionP-T1182N181.70 in. 225 versionP-T1182G181.62 in. Lead Length8 in. Outside Diameter15 versionP-T1182F182.65 in. 30 versionP-T1182H183.00 in. 50 versionP-T1182J183.25 in. 80 versionP-T1182L183.5 in. 120 versionP-T1182M184.25 in. 160 versionP-T1182N184.25 in. 225 versionP-T1182G184.5 in. Parallel Secondary15 versionP-T1182F1818V @ 0.84A 30 versionP-T1182H1818V @ 1.66A 50 versionP-T1182J1818V @ 2.78A 80 versionP-T1182L1818V @ 4.44A 120 versionP-T1182M1818V @ 6.66A 160 versionP-T1182N1818V @ 8.88A 225 versionP-T1182G1818V @ 12.5A Series Secondary15 versionP-T1182F1836V C.T. @ 0.420A 30 versionP-T1182H1836V C.T. @ 0.83A 50 versionP-T1182J1836V C.T. @ 1.39A 80 versionP-T1182L1836V C.T. @ 2.22A 120 versionP-T1182M1836V C.T. @ 3.33A 160 versionP-T1182N1836V C.T. @ 4.44A 225 versionP-T1182G1836V C.T. @ 6.25A Toroid CenterOpen Packaging Dimensions15 versionP-T1182F182.65 in. × 2.65 in. × 1.2 in. 30 versionP-T1182H183 in. × 3 in. × 1.4 in. 50 versionP-T1182J183.25 in. × 3.25 in. × 1.5 in. 80 versionP-T1182L183.5 in. × 3.5 in. × 1.5 in. 120 versionP-T1182M184 in. × 4 in. × 1.63 in. 160 versionP-T1182N184.35 in. × 4.35 in. × 1.75 in. 225 versionP-T1182G184.5 in. × 4.5 in. × 2 in. Weight (Packaging)15 versionP-T1182F180.5 lbs. 30 versionP-T1182H181.75 lbs. 50 versionP-T1182J181.75 lbs. 80 versionP-T1182L183 lbs. 120 versionP-T1182M183 lbs. 160 versionP-T1182N183.6 lbs. 225 versionP-T1182G185.3 lbs. Files Specification Sheet for 15P-T1182F18 Specification Sheet for 225P-T1182G18 Specification Sheet for 30P-T1182H18 Specification Sheet for 50P-T1182J18 Specification Sheet for 80P-T1182L18 Specification Sheet for 120P-T1182M18 Specification Sheet for 160P-T1182N18 13093682 0623980531151 5.3000lbs 0.00 0.00 0.00
Hammond Manufacturing
74.88 2025-04-26 In Stock

Hammond P-T1182-18 Transformer - Hammond, Toroidal Power, 18V / 36V secondary

Shop more from CED

UPC: 0623980531151
SKU: CED-P-T1182-18
Price: $74.88
Va rating:
Quantity:
In Stock
*  Click "Add to Cart" to calculate shipping and delivery time.
Share & Earn 10% Cash Back Best Price in Bulk

Product Description

Manufacturer Part Number: P-T1182-18

Dual 117/234 VAC primary, 50/60 Hz. operation. 36 V series, 18 V parallel secondary.

Toroidal transformers are

  • low profile
  • lightweight
  • cool running / high efficiency
  • have low stray magnetic flux leakage (low EMI) due to core shape


Features:

  • Supplied with two neoprene rubber insulating pads, one metal centering washer and all mounting hardware
  • Minimum 8" long flexible leads
  • Manufactured using Class B (130 degree C) materials.
  • Hi-Pot test of 4,000VAC RMS between primary & secondary
  • UL recognized to UL506 (XPTQ2.Guide) UL file #E207860
  • CSA certified to C22.2 #66 - CSA file #209651
  • CE compliant to IEC 61558-2-4


Note: Units are designed to have all windings engaged (either series or parallel connected) or connected as an autotransformer.

Note about Inrush Current: Due to the superior magnetic properties of Toroidal transformers they will be susceptible to high magnetizing current when initially energized, only limited by the low DC resistance of the primary winding. Depending on where you are in the AC cycle when the transformer is energized dictates the chances of overloading the supply circuit. This is why the transformer may sometimes energize without a problem and other times it will blow the fuse or trip the circuit breaker. The duration of this overload is rarely longer than a half of a cycle. Therefore, you should consider using a slow-blow fuse, time delayed circuit breaker or other form of soft start circuitry for the supply line when using these high efficient Toroidal transformers.



For other toroidal secondary voltages, see our other listings:



Measurements and Specs




Files

warning tips WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov.
Need more information?
Our staff are available to answer any questions you may have about this item


Customer Reviews
0 reviews
Be the first to review this item!