skip to footer block
MEO White Rodgers 50A56 956 York Oem Direct Replacement Control Includes Bracket P7570563MEO-307492 https://cdnimages.opentip.com/full/MEO/MEO-307492.jpg White Rodgers 50A56 956 York Oem Direct Replacement Control Includes Bracket Manufacturer Part Number: 50A56-956Part Description: Integrated Hot Surface Furnace Control Kit Type 1-Stage, Non-Integrated Fuel Type Natural, Manufactured, Mixed, Liquefied Petroleum and Liquid Propane Gas Air Mixture Flame Sense Type Direct/Indirect Ignition Source Hot Surface Prepurge Time 0 Second Flame Failure Response Time 2 Second Valve Rating 1.5 Amp at 25 Volt AC 50/60 Hertz Power Rating 25 Volt AC at 50/60 Hertz Size 4.825 Inch Width x 1.25 Inch Depth x 7 Inch Height Temperature Rating -40 to 175 Deg F Application Furnace Approval CSA (Canada and US) Igniter Rating 6 Amp at 120 Volt AC 50/60 Hertz (Resistive) Inducer Relay Rating 2.2 Amp FLA to 3.5 Amp LRA at 120 Volt AC Circulator Relay Rating 14.5 Amp FLA to 25 Amp LRA at 120 Volt AC Humidity 5 to 93 Percent (Non-Condensing) Ignition Activation Period 2 Second Valve Sequence Period 21 Second Interpurge Time 15 Second Post Purge Time 15 Second Lockout Time 140 Second Auto Reset Time 60 MinuteFeatures / Benefits Controls Gas Valve, Igniter, Blower, Inducer, Humidifier and Air Cleaner System Diagnostic LED with Fault Recall Twinning Connection Fused to Protect Low Voltage System Transformer Selectable Continuous Fan Speed Third Fan Speed 2-Stage Cooling Y2 Input 7570563 00786710548673 10.8000lbs 0.00 0.00 0.00
White-Rodgers
84.09 2025-05-26 8 In Stock
customer review - by , February 2, 2018
5/ 5stars
good product
customer review - by , January 1, 2018
5/ 5stars
Was a little different then what is pictured but still was easy to replace the old board and it fixed the problem with the furnace
customer review - by , January 1, 2018
5/ 5stars
life saver was a plug and chug easy swap works great
customer review - by , December 12, 2017
5/ 5stars
Unit came quickly and fixed my furnace for a lot less than a technician Thank you
customer review - by , November 11, 2017
4/ 5stars
Though not a direct plug in for my older unit it has been working well for over a year now I just had to remove it from the metal plate and found out my old unit uses the high fan not low fan connection
customer review - by , October 10, 2017
5/ 5stars
Worked 100 perfectly to replace my 17yr old Air Handler from York where the control board went bad on I bought 2 since my house has 2 ACs and replaced both even though only a single failed as I’m sure that the other would be soon behind
customer review - by , August 8, 2017
5/ 5stars
Great part easy to install thanks
customer review - by , June 6, 2017
5/ 5stars
Just as described
customer review - by , June 6, 2017
5/ 5stars
If I told you how simple it was to diagnose the problem buy and install this board; you might not believe it What you can believe is the money I saved versus paying a technician) was more than enough to buy me and the wife a weekend at a resort Money very well spent Delivery was super fast
customer review - by , August 8, 2016
5/ 5stars
Easy replacement both heating and cooling now working

White-Rodgers 50A56-956 York Oem Direct Replacement Control - Includes Bracket, Price/each

stars Rating 5 | 11 reviews
Shop more from MEO

UPC: 00786710548673
SKU: MEO-307492
Price: $84.09
Buy in bulk & save 6% ($79.18 each)
Quantity:
8 In Stock
*  Click "Add to Cart" to calculate shipping and delivery time.
Share & Earn 10% Cash Back Best Price in Bulk
Price: $84.09 ea X 1 qty = $84.09
Quantity Price Save
1+ $84.09 0%
5+ $82.68 2%
10+ $79.18 6%
This item is excluded from use of other offer, discount or coupon.

Product Description

Price is for each.

Manufacturer Part Number: 50A56-956

Part Description:
  • Integrated Hot Surface Furnace Control Kit
  • Type 1-Stage, Non-Integrated
  • Fuel Type Natural, Manufactured, Mixed, Liquefied Petroleum and Liquid Propane Gas Air Mixture
  • Flame Sense Type Direct/Indirect
  • Ignition Source Hot Surface
  • Prepurge Time 0 Second
  • Flame Failure Response Time 2 Second
  • Valve Rating 1.5 Amp at 25 Volt AC 50/60 Hertz
  • Power Rating 25 Volt AC at 50/60 Hertz
  • Size 4.825 Inch Width x 1.25 Inch Depth x 7 Inch Height
  • Temperature Rating -40 to 175 Deg F
  • Application Furnace
  • Approval CSA (Canada and US)
  • Igniter Rating 6 Amp at 120 Volt AC 50/60 Hertz (Resistive)
  • Inducer Relay Rating 2.2 Amp FLA to 3.5 Amp LRA at 120 Volt AC
  • Circulator Relay Rating 14.5 Amp FLA to 25 Amp LRA at 120 Volt AC
  • Humidity 5 to 93 Percent (Non-Condensing)
  • Ignition Activation Period 2 Second
  • Valve Sequence Period 21 Second
  • Interpurge Time 15 Second
  • Post Purge Time 15 Second
  • Lockout Time 140 Second
  • Auto Reset Time 60 Minute


Features / Benefits

  • Controls Gas Valve, Igniter, Blower, Inducer, Humidifier and Air Cleaner
  • System Diagnostic LED with Fault Recall
  • Twinning Connection
  • Fused to Protect Low Voltage System Transformer
  • Selectable Continuous Fan Speed
  • Third Fan Speed
  • 2-Stage Cooling Y2 Input

warning tips WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov.

Note

This product is not eligible for coupon code discount, for we've been offering the best price in the market.
Need more information?
Our staff are available to answer any questions you may have about this item


Look Similar Items By Category


Customer Reviews
5 stars
10
4 stars
1
3 stars
0
2 stars
0
1 stars
0
By R. Kolbuch
Date: February 28, 2018
good product
Rating: 5 stars [5 of 5 Stars!]
By Ronald Ramaut
Date: January 12, 2018
Was a little different then what is pictured but still was easy to replace the old board and it fixed the problem with the furnace
Rating: 5 stars [5 of 5 Stars!]
By Jeffrey Nickell
Date: January 01, 2018
life saver was a plug and chug easy swap works great
Rating: 5 stars [5 of 5 Stars!]
By James D.
Date: December 16, 2017
Unit came quickly and fixed my furnace for a lot less than a technician Thank you
Rating: 5 stars [5 of 5 Stars!]
By Gene Ormond
Date: November 10, 2017
Though not a direct plug in for my older unit it has been working well for over a year now I just had to remove it from the metal plate and found out my old unit uses the high fan not low fan connection
Rating: 4 stars [4 of 5 Stars!]
By Scott S.
Date: October 10, 2017
Worked 100 perfectly to replace my 17yr old Air Handler from York where the control board went bad on I bought 2 since my house has 2 ACs and replaced both even though only a single failed as I’m sure that the other would be soon behind
Rating: 5 stars [5 of 5 Stars!]
Items 1 - 6 of 11 reviews