Items 1 - 20 of 40 reviews
 1  2  [Next] 
By B. Winckler
Date: October 08, 2023
Even though it doesn't look like the one being replaced, the description stated it was for my furnace. I installed it, and it works perfectly. Couldn't be more happy!
Rating: [5 of 5 Stars!]
By Cheryl Dodson
Date: September 30, 2023
This board worked well. Unfortunately, the Surburban NT 34 heater is a piece of junk. Have replaced so many parts, now it's time to just find a different heat source.
Rating: [5 of 5 Stars!]
By BRIAN MCGARTY
Date: September 09, 2023
a small difference in design but fit perfectly
Rating: [5 of 5 Stars!]
By A Customer
Date: August 27, 2023
Furnace would not throw heat, only cold air. Troubleshooting problem pointed me to the circuit board - thermostat would start furnace cycle, no gas smelled and no ignition. Tested gas solenoid to be good - speculated problem to be circuit board. Ordered part, and it fixed the problem.
Rating: [5 of 5 Stars!]
By Greg
Date: June 19, 2023
I thought my module was burnt out. The wires were just switched and it won't work when the polarity is off. Now I have two.
Rating: [5 of 5 Stars!]
By J. Simpson
Date: May 03, 2023
Our NT20SEQ furnace in our 2016 HW296 went out, of course when it was in the 30's...brrrrrAfter reading forums, I replaced the igniter, then the sail switch, then the control board. The control board was the culprit.Once the thermostat was tuned on, our furnace fan would run, then the propane switch would open (click), but the igniter was not sparking (no clicks), thus no ignition. The cycle would repeat 3 times before the fan would shut off.If you have propane in your tank, and your fan runs, you should smell propane at the exhaust (outside the camper, at the rear of the furnace) when the propane switch opens (click. If if you do, then you know propane is making it into the furnace, and that your sail switch is giving the OK to send fuel. At this point I would inspect your igniter, because it's the easiest part to examine. If you don't suspect the igniter, go for the control board.This board was a little larger, and the 2 power terminals were on the side rather than the top. Everything was plug and play though, except I needed to tap a screw hole for a 2nd screw since only one would line up to the 4 furnace existing screw holes. There were only 2 screws holding the original.Hope this helps!
Rating: [5 of 5 Stars!]
By Claude Michel Max Salois
Date: February 21, 2023
Works very goodright away.
Rating: [5 of 5 Stars!]
By Markster90
Date: January 31, 2023
Highly recommend this manufacturer. At first look anyone can tell it is a well made circuit board. Completely coated in pertective coating. Solder joints perfect. Confident I will get years of service from it.
Rating: [5 of 5 Stars!]
By SR
Date: January 20, 2023
These imported control boards are poorly made. The onboard relays don't work and/or the boards fail after only a few months.
Rating: [1 of 5 Stars!]
By David Brown
Date: January 03, 2023
My suburban furnace would not stay lit, igniter would fail after 3 times. This fixed it perfectly. Search YT as I did not have to remove furnace to get. Park out.
Rating: [5 of 5 Stars!]
By RV Tech Time, LLC
Date: January 01, 2023
Used for a customer.
Rating: [5 of 5 Stars!]
By Greg
Date: December 26, 2022
Works excellent
Rating: [5 of 5 Stars!]
By Michael LaClair
Date: December 23, 2022
Be Advised! This will update the old one...comes with a A updated hardware ..will appear to be the wrong one ..
Rating: [4 of 5 Stars!]
By M C H
Date: December 19, 2022
Works great- easy to install
Rating: [5 of 5 Stars!]
By randdogs
Date: November 27, 2022
they sent one that was defective and then sent one out right away and worked perfect we really appreciate getting the replacement that quick all is good have heat again and could not be happier
Rating: [5 of 5 Stars!]
By Bruce Althen
Date: November 11, 2022
Simple replacement for a 27 year old part
Rating: [5 of 5 Stars!]
By Carolyn M
Date: September 09, 2022
This board will work on an older SF35. Instructions for fan control connections would have been nice since the furnace has a time delay relay. Decided not to use jumper wires on these connections and the furnace works fine.
Rating: [5 of 5 Stars!]
By John P.
Date: August 06, 2022
Spendy but works every time so far . 18 months installed. Works like a charm. Little sloppy work.
Rating: [5 of 5 Stars!]
By A Customer
Date: April 19, 2022
Installed and connected. Worked first time. No problems.
Rating: [5 of 5 Stars!]
By Weyman Swilley
Date: April 14, 2022
A job to get to since the rv manufacturer installed the furnace wall cavity. Had to install an external access.
Rating: [5 of 5 Stars!]